Headstar V2

Reference: 00032098 https://difra.be/web/image/product.template/54153/image_1920?unique=77357f3

DI 140504 : Headstar v.2 Monocular system with goggles (hardware only) with integrated fixation led
Select necessary modules for requested tests

0,00 € / 15 Days

Not Available For Sale

Rental Period (UTC + 01:00)

This combination does not exist.

Pricing
15 Days 0,00 €
30 Days 250,00 €
60 Days 500,00 €

Terms and Conditions
30-day money-back guarantee
Shipping: 2-3 Business Days

SYSTÈME HEADSTAR

Connected to a computer, HEADSTAR locates the center of each pupil in real time and records head movements.

HEADSTAR is built around a digital camera (USB 2.0) with a native resolution of 307,200 pixels and high sensitivity (0.1 lux).

The use of Region of Interest (ROI) on the camera eliminates the need for any mechanical adjustment to center the pupil in the video. As an option, HEADSTAR can even detect twisting eye movements.


As far as recording frequency is concerned, HEADSTAR is capable of recording eye movements with a maximum frequency of 200Hz in VNG mode and 250Hz in vHIT mode.


Certified biocompatible padding foams (phthalate-free, hypoallergenic) ensure that HEADSTAR eyewear is comfortable and suitable for children too.

HEADSTAR is supplied in a carrying case with accessories: mask, cover and 3 sets of foams.

Design to avoid slippage, this goggle ables you to perform regular VNG test as well as video head impulse test. 
Thank's to the built it 6 DOF gyroscope/accelerometer and USB HUB that allow us to use only one USB cable to connect to the computer. 

Lightweight, comfortable, delivered with a cover for vision denied, it's a robust goggle for daily use in your practice.
The external focus knob able you to get a sharp image for the best eye tracking ever !

Bio compatible foam is used and can be cleaned and change when they are too old.

Just add the type of software you want : EASY-Line or PRO-Line and let's go !

Features

Technical specifications

Frame rate

Recording frequency can be selected from 50Hz up to 250Hz

USB 2.0

Real full USB 2.0 camera with 4.5 meter cable. Direct connection on your laptop.

Eye tracking

Unique eye tracking algorithm that avoid problems with eye blinking, mascara, heavy eye lids, ...

High resolution

High resolution IR camera. At 250Hz, the resolution is still 320x240 pixels to ensure high quality results.

Lightweight

Less than 200gr for the camera box excluding the USB cable. Cover for vision denied included.

Ergonomic

Confortable goggle that fits to adult and children patient with a great confort.

Software capabilities

Add a great slogan.

Number of channels

HeadStar can record X-Y eye movement but also torsional eye movement and the pupil diameter. A real 4 channels !

Fixation light

Built in fixation light for either performing a fixation in caloric testing or to perform the VHIT SHIMP test.

Sample Icons

All these icons are completely free for commercial use.

Edit Styles

You can edit colors and backgrounds to highlight features.

Sample Icons

All these icons are completely free for commercial use.

Great Value

Turn every feature into a benefit for your reader.

                  DISOFT II

                  HEADSTAR must be accompanied by software.
                  Two options are available: EasyVNG or DISOFT II. Easy VNG is a simple "click and play" solution.
                  DISOFT II is the fully configurable and customizable software.
                  Both are powerful data processing programs that simplify the doctor's task.
                  Depending on the tests performed, the software analyzes and measures various parameters:

                  • number of twitches or eye movements

                  • amplitude, frequency

                  • speed of the slow phase of nystagmus

                  • latency, phase, distortion

                  • gain

                  • symmetry or asymmetry of responses

                  • labyrinthine, directional paresis or hypoexitability

                  • preponderance of nystagmus

                  • measurement of ocular fixation indices